<Parameter>
<ParameterFamily>head</ParameterFamily>
<LongName>
focus_error_thresh
</LongName>
<Name>
fthresh
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Thermal</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Specifies the focus error threshold. Focus error measurements larger than this
for a duration set by the ferrdur value indicate that the media is out of focus
and generate a workstation warning message at the end of the plot. Setting
fthresh to 0 disables checking for focus error out of range.
</text></DescriptionText>
<DescriptionText><text>
This parameter should never be 0 for any head in the field.
</text></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>150</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 32767</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/head_cfg_ferrdur.xml</LinkAddress><LinkTitle>NVS: head ferrdur</LinkTitle></Link></li>
<li><Link><LinkAddress>../error_messages/17664.xml</LinkAddress><LinkTitle>Error: E_HEAD_FOCUS_OUT_OF_RANGE</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:05 2008 PST
</Updated>
<Links>
</Links>
</Parameter>